================================================================== LYNX APPolo | Control Server - RELEASE 8.14.1 COMPATIBLE with LYNX APPolo | Control GUI 8.14.0 and above ------------------------------------------------ Device specific enhancements * Added support for transmission of output signals on SFP 5/6 of DVD 5480 TO (version 950 and above), using TR-type SFPs ================================================================== LYNX APPolo | Control Server - RELEASE 8.14.0 COMPATIBLE with LYNX APPolo | Control GUI 8.14.0 and above ------------------------------------------------ Enhancements in Server functionality + Added SNMP get/set access to yellobriks attached via RCT 1012 (requires software option OC_RSLRCTI or OC_RSLSNMP) + Added possibility to rename yellobriks attached via RCT 1012 Device specific enhancements + Added support for new product group OET19x0 + Added support for new hardware revision of DVD14xx and DVD18xx ================================================================== LYNX APPolo | Control Server - RELEASE 8.13.0 COMPATIBLE with LYNX APPolo | Control GUI 8.13.0 and above ------------------------------------------------ Device specific enhancements + Added support for RCT 1012 + Added support for all existing yellobrik products that can be connected to RCT 1012 * Added support for psF-to-p conversion in PVD5810 (v849 and above) ================================================================== LYNX APPolo | Control Server - RELEASE 8.12.0 COMPATIBLE with LYNX APPolo | Control GUI 8.12.0 and above ------------------------------------------------ Device specific enhancements + Added support for OTR 5444 * Improved dual-mux operation of DVD 5480 HO ================================================================== LYNX APPolo | Control Server - RELEASE 8.11.1 (Apr 24 2020) COMPATIBLE with LYNX APPolo | Control GUI 8.11.0 and above ------------------------------------------------ Improvements in Server functionality * Improved NTP operation on Colibri iMX6 platform ================================================================== LYNX APPolo | Control Server - RELEASE 8.11.0 (Oct 16 2019) COMPATIBLE with LYNX APPolo | Control GUI 8.11.0 and above ------------------------------------------------ Device specific enhancements + added support for DVD 5480-H ================================================================== LYNX APPolo | Control Server - RELEASE 8.10.0 (Sep 03 2019) COMPATIBLE with LYNX APPolo | Control GUI 8.10.0 and above ------------------------------------------------ Device specific enhancements + added support for DVD 5480-TO + added support for DVD 5480-HO ================================================================== LYNX APPolo | Control Server - RELEASE 8.9.1 (May 22 2019) COMPATIBLE with LYNX APPolo | Control GUI 8.9.0 and above ------------------------------------------------ Device specific enhancements and improvements * OTX5840: solved an issue where SPF1 and SFP2 presentation was swapped ================================================================== LYNX APPolo | Control Server - RELEASE 8.9.0 (Mar 18 2019) COMPATIBLE with LYNX APPolo | Control GUI 8.9.0 and above ------------------------------------------------ Enhancements in Server functionality + Added support for new server hardware Device specific enhancements and improvements + DAA5320: added customizable delay for silence detection * PTG5610: solved an issue where pattern selection got lost after GUI restart ================================================================== LYNX APPolo | Control Server - RELEASE 8.8.5 (Apr 9 2018) COMPATIBLE with LYNX APPolo | Control GUI 8.8.0 and above ------------------------------------------------ Device specific enhancements + Added PDM5280 SRC control parameters ================================================================== LYNX APPolo | Control Server - RELEASE 8.8.4 (Apr 4 2018) COMPATIBLE with LYNX APPolo | Control GUI 8.8.0 and above ------------------------------------------------ Improvements in Server functionality * Improved server response time for Auto Control rules created with PDM5290 Device specific enhancements + Added possibility to disable PDM5290 video output in case of no input + Added PDM5290 SRC control parameters + Added PDM5280 possibility to disable the audio mute period in case of standard changes ================================================================== LYNX APPolo | Control Server - RELEASE 8.8.3 (Feb 1 2018) COMPATIBLE with LYNX APPolo | Control GUI 8.8.0 and above ------------------------------------------------ Device specific enhancements + Added output-if-no-input control for PDM5290 (SW label 845 and above) ================================================================== LYNX APPolo | Control Server - RELEASE 8.8.2 (Jan 19 2018) COMPATIBLE with LYNX APPolo | Control GUI 8.8.0 and above ------------------------------------------------ Device specific enhancements + Added input-to-reference tolerance control for PDM5290 ================================================================== LYNX APPolo | Control Server - RELEASE 8.8.1 (Nov 18 2016) COMPATIBLE with LYNX APPolo | Control GUI 8.8.0 and above ------------------------------------------------ Improvements in Server functionality * Stability and performance improvements ================================================================== LYNX APPolo | Control Server - RELEASE 8.8.0 (Nov 7 2016) COMPATIBLE with LYNX APPolo | Control GUI 8.8.0 and above ------------------------------------------------ Device specific enhancements + Added support for Expected Input Standard Setting of PVD5802 ================================================================== LYNX APPolo | Control Server - RELEASE 8.7.9 (Aug 3 2016) COMPATIBLE with LYNX APPolo | Control GUI 8.7.0 and above ------------------------------------------------ Improvements in Server functionality * Solved an issue in the Cluster Manager where long delays in the server-to-server communication could lead to a status changeover * Solved an issue in the memory management which could occur in some special cases after a longer time. When occurred the server did not respond to network communication anymore ================================================================== LYNX APPolo | Control Server - RELEASE 8.7.8 (Jul 29 2016) COMPATIBLE with LYNX APPolo | Control GUI 8.7.0 and above ------------------------------------------------ Improvements in Server functionality * Solved an issue where the AutoControl engine could trigger actions prematurely after server restart or rescan ================================================================== LYNX APPolo | Control Server - RELEASE 8.7.7 (Jul 20 2016) COMPATIBLE with LYNX APPolo | Control GUI 8.7.0 and above ------------------------------------------------ Improvements in Server functionality * Added optional delay for execution of AutoControl rules * Added multi-level logging of SNMP activities ================================================================== LYNX APPolo | Control Server - RELEASE 8.7.6 (Jul 12 2016) COMPATIBLE with LYNX APPolo | Control GUI 8.7.0 and above ------------------------------------------------ Improvements in Server functionality * Added SNMP support for PDM5240 version 743 ================================================================== LYNX APPolo | Control Server - RELEASE 8.7.5 (Jun 29 2016) COMPATIBLE with LYNX APPolo | Control GUI 8.7.0 and above ------------------------------------------------ Improvements in Server functionality * Solved an issue where the restore of device settings has led to a short input signal loss indication ================================================================== LYNX APPolo | Control Server - RELEASE 8.7.4 (Jun 22 2016) COMPATIBLE with LYNX APPolo | Control GUI 8.7.0 and above ------------------------------------------------ Improvements in Server functionality * Solved an issue in CustomControl where the parameters in a custom design were not anymore reachable after fail-over in a cluster of redundant APPolo servers * Added the action configuration of server events to the backup of the server node ================================================================== LYNX APPolo | Control Server - RELEASE 8.7.3 (May 31 2016) COMPATIBLE with LYNX APPolo | Control GUI 8.7.0 and above ------------------------------------------------ Device specific improvements * TT Sfp Sticks: fixed wavelength information ================================================================== LYNX APPolo | Control Server - RELEASE 8.7.2 (May 17 2016) COMPATIBLE with LYNX APPolo | Control GUI 8.7.0 and above ------------------------------------------------ Improvements in Server functionality * Backup File Management: improved stability + Added SNMP interface for monitoring cluster status information ================================================================== LYNX APPolo | Control Server - RELEASE 8.7.0 (Feb 23 2016) COMPATIBLE with LYNX APPolo | Control GUI 8.7.0 and above ------------------------------------------------ Device specific enhancements + PDM5290: added possibility not to insert metadata in output when the source is unavailable ================================================================== LYNX APPolo | Control Server - RELEASE 8.6.3 (Feb 3 2016) COMPATIBLE with LYNX APPolo | Control GUI 8.6.0 and above ------------------------------------------------ Enhancements in Server functionality + Added possibility to overrule event levels to one single level for all modules Improvements in Server functionality * Solved update issue for events and resulting LED color of some modules in special cases ================================================================== LYNX APPolo | Control Server - RELEASE 8.6.2 (Feb 1 2016) COMPATIBLE with LYNX APPolo | Control GUI 8.6.0 and above ------------------------------------------------ Improvements in Server functionality * Revised display of long haul SFP information in APPolo GUI main views ================================================================== LYNX APPolo | Control Server - RELEASE 8.6.0 (Dec 22 2015) COMPATIBLE with LYNX APPolo | Control GUI 8.6.0 and above ------------------------------------------------ Enhancements in Server functionality + SNMP Traps can now be configured via device parameters + Read Subscriptions can now be configured (UI_QUICK_PARAMETER_UPDATES) as fast (TRUE, legacy and default mode) or reliable (FALSE, new mode) [Fast will lead to a RS response after the write command has been sent to the LYNX card (few milliseconds), reliable will lead to a RS response after the LYNX server has received the acknowledgment from the LYNX card (~ 2 seconds)] ================================================================== LYNX APPolo | Control Server - RELEASE 8.5.0 (Nov 26 2015) COMPATIBLE with LYNX APPolo | Control GUI 8.5.0 and above ------------------------------------------------ Device specific enhancements + Added UI support for RFR5041_2 ================================================================== LYNX APPolo | Control Server - RELEASE 8.4.2 (Oct 16 2015) COMPATIBLE with LYNX APPolo | Control GUI 8.4.0 and above ------------------------------------------------ Enhancements in Server functionality * Stability improvements ================================================================== LYNX APPolo | Control Server - RELEASE 8.4.1 (Sep 17 2015) COMPATIBLE with LYNX APPolo | Control GUI 8.4.0 and above ------------------------------------------------ Enhancements in Server functionality + Added logging of device lock operations to the server logfile + Added logging of user preset operations to the server logfile * Improved Remote Interface communication and read subscription functionality * Smaller improvements ================================================================== LYNX APPolo | Control Server - RELEASE 8.4.0 (Sep 1 2015) COMPATIBLE with LYNX APPolo | Control GUI 8.4.0 and above ------------------------------------------------ Enhancements in Server functionality + Show influence from module events on Master LED * Solved an issue where video timing card settings could be changed after GUI has been opened * Smaller improvements Device specific enhancements + Added UI support for CMX5710 ================================================================== LYNX APPolo | Control Server - RELEASE 8.3.0 (Jun 12 2015) COMPATIBLE with LYNX APPolo | Control GUI 8.3.0 and above ------------------------------------------------ Improvements in Server functionality * Revised an issue where a custom device name could not be modified via a SNMP SET request * Revised an issue where a change of a float parameter via the RemoteIF to an illegal value was not clipped to the pre-defined min/max range Device specific enhancements + Added new device OET5501 Device specific improvements * PVD5800: active user preset parameter writable ================================================================== LYNX APPolo | Control Server - RELEASE 8.2.1 (Apr 24 2015) COMPATIBLE with LYNX APPolo | Control GUI 8.2.0 and above ------------------------------------------------ Improvements in Server functionality * Corrected switching of float parameters via Remote IF which did not work properly with server version 8.2.0 ================================================================== LYNX APPolo | Control Server - RELEASE 8.2.0 (Apr 2 2015) COMPATIBLE with LYNX APPolo | Control GUI 8.2.0 and above ------------------------------------------------ New features & enhancements in Server functionality + Added new feature: APPolo Server can sync its internal clock to a NTP time-server - Removed support for X-board platform (RCT5030 and RCP5000) Improvements in Server functionality * Extended log will now record performance statistics to server logfiles * Revised an issue where the RCP button state conditions mistakenly switched to "true" when a removed device comes back * Corrected RemoteIF query for parameter "displayName" * RCP5044 does now prevent from entering the setup menu when running a custom configuration * Improved RCT5031 login speed with GUI ================================================================== LYNX APPolo | Control Server - RELEASE 8.1.3 (Feb 12 2015) COMPATIBLE with LYNX APPolo | Control GUI 8.1.0 and above ------------------------------------------------ Improvements in Server functionality * Improvement of internal user management * Improved handling of system clock changes, e.g. during time synchronization in server cluster ================================================================== LYNX APPolo | Control Server - RELEASE 8.1.2 (Jan 20 2015) COMPATIBLE with LYNX APPolo | Control GUI 8.1.0 and above ------------------------------------------------ Improvements in Server functionality * Revised transfer of CustomControl designs to the APPolo Design app on iOS ================================================================== LYNX APPolo | Control Server - RELEASE 8.1.1 (Jan 9 2015) COMPATIBLE with LYNX APPolo | Control GUI 8.1.0 and above ------------------------------------------------ Improvements in Server functionality * Added security functionality for RCT5030 and RCP5000 * Revised rescan function used when attaching RCT5021 ================================================================== LYNX APPolo | Control Server - RELEASE 8.1.0 (Dec 19 2014) COMPATIBLE with LYNX APPolo | Control GUI 8.1.0 and above ------------------------------------------------ New features & enhancements in Server functionality + LYNX Server Options are now available as time limited demo licenses Improvements in Server functionality * Improvement of internal user management * Several smaller improvements ================================================================== LYNX APPolo | Control Server - RELEASE 8.0.0 (build 630, Aug 19 2014) COMPATIBLE with LYNX APPolo | Control GUI 8.0.0 and above ------------------------------------------------ New features & enhancements in Server functionality + Added new feature User Management + Added new feature CustomControl Improvements in Server functionality * Backup: Backup of device now contains event configuration Device specific improvements * Scaler Parameter ConvX/AspectInSelect shall read 16:9 in case of HDTV * PVD5810: Revised sample rate converter parameter mapping Device specific enhancements + Added UI support for PDA5280 + Added UI support for PVD5802 + PDM5290: Added support for SourceID embedding/deembedding + PDM5290: Added FrameSync option + PVD5810: Added display for external sample rate converters ===================================================================== LYNX APPolo | Control Server - RELEASE 7.3.1 (build 611, Mar 11 2014) COMPATIBLE with LYNX APPolo | Control GUI 7.3.0 and above ------------------------------------------------ Improvements in Server functionality * Revised Remote Interface regarding redundant server status ===================================================================== LYNX APPolo | Control Server - RELEASE 7.3.0 (build 607, Feb 27 2014) COMPATIBLE with LYNX APPolo | Control GUI 7.3.0 and above ------------------------------------------------ Enhancements in Server functionality + Added new Redundant Servers feature + Added Auto Control for Server RCT5031 Improvements in Server functionality * Optimized backup job progress information viewed * Revised permissions for Read Only parameters in User Access Feature Device specific features + PVD5840: current settings information in User Presets + PVD5840: Added current settings information in User Presets Device specific improvements * PVD5840: Revised Scaler Parameter ConvX/AspectInSelect shall read 16:9 in case of HDTV ===================================================================== LYNX APPolo | Control Server - RELEASE 7.2.0 (build 603, Feb 6 2014) COMPATIBLE with LYNX APPolo | Control GUI 7.2.0 and above ------------------------------------------------ Optimizations in Server functionality * WebIF: User Management restart dialog revised * Optimized communication with GUI Connection Manager if IP address is in different IP range * other optimizations Device specific features + Added UI support for RFR 5041-1 and RFR 5041-1S + PVD 5800/5810/5660: Added indication of last loaded user preset and modification state + PDM 5280/5290: Added indication of last loaded user preset and modification state * DVD5820-Relay: revised output crossbar control ===================================================================== LYNX APPolo | Control Server - RELEASE 7.1.1 (build 588, Nov 25 2013) COMPATIBLE with LYNX APPolo | Control GUI 7.0.0 and above ------------------------------------------------ Fixes in Server functionality - Fixed support for optical SFPs ===================================================================== LYNX APPolo | Control Server - RELEASE 7.1.0 (build 584, Oct 25 2013) COMPATIBLE with LYNX APPolo | Control GUI 7.0.0 and above ------------------------------------------------ New features & enhancements in Server functionality - Added support for optical multi-mode SFPs Device specific bugs / fixes - PDM 5289: Fixed bug in ANC deletion - PDM 5289: Added UI parameter OutputLineField2 ===================================================================== LYNX APPolo | Control Server - RELEASE 7.0.2 (build 583, Oct 9 2013) COMPATIBLE with LYNX APPolo | Control GUI 7.0.0 and above ------------------------------------------------ Fixes in Server functionality - #2699: RemoteIF does not send subscriber updates Fixes in Panel Controller functionality - #2697: RCP application of APPolo Server 7.0.0 does not connect to local server ===================================================================== LYNX APPolo | Control Server - RELEASE 7.0.0 (build 579, Sep 25 2013) COMPATIBLE with LYNX APPolo | Control GUI 7.0.0 and above ------------------------------------------------ Enhancements in Server functionality - Added AutoControl Base - Added GPI Trigger Control Fixes in Server functionality - Fixed slow switching of user presets caused by consecutive preset switch command sent to the same device very quickly - #2484 - Logfile does not show UTF-8 encoded user name and comment of SmartUpdate jobs correctly - #2586 - RemoteIF: Connection reset by the client can crash the APPolo server - #2620 - Rescanning devices - #2646 - APPolo Server identifies backup jobs as SmartUpdate jobs mistakenly Device specific bugs / fixes - #2643 - DVD5810: Meaningless SourceOut Parameter - PVD5822: removed inactive DelayPulseAssign Parameter (Timing Tab) - #2465 - RCT5031, SW 377: C2-assisted backup occasionally fails in state WaitingForInitialData ===================================================================== LYNX APPolo | Control Server - RELEASE 6.5.0 (build 573, Aug 12 2013) COMPATIBLE with LYNX APPolo | Control GUI 6.5.0 and above ------------------------------------------------ Fixes in Server functionality - Changed default behaviour of automatic device rescan to depend on the controller type RCT 5020/5021/5030/5031 and RFR 5003/5004/5041: No automatic rescan RCT 5022/5023: Automatic rescan immediately after detection of data loss Operation can still be customized with config variable DEVICE_AUTO_RESCAN_PERIOD Device specific features - Added UI support for PDM 5290 D/U - Added Test Tone support for PVD 5840 ===================================================================== LYNX APPolo | Control Server - RELEASE 6.4.0 (build 569, Jul 5 2013) COMPATIBLE with LYNX APPolo | Control GUI 6.3.0 and above ------------------------------------------------ Fixes in Server functionality - #2650 - APPolo server loses custom device names when restoring backup files Device specific features - Added UI support for PDM 5280 D/U/DO/UO - Added UI support for PDM 5240 D/U ===================================================================== LYNX APPolo | Control Server - RELEASE 6.3.3 (build 568, Jul 2 2013) COMPATIBLE with LYNX APPolo | Control GUI 6.3.0 and above ------------------------------------------------ Fixes in Server functionality - Added config variable DEVICE_AUTO_RESCAN_PERIOD, enabling customization of automatic device rescan ===================================================================== LYNX APPolo | Control Server - RELEASE 6.3.2 (build 566, Jun 26 2013) COMPATIBLE with LYNX APPolo | Control GUI 6.3.0 and above ------------------------------------------------ Fixes in Server functionality - #2619: RCP5044: Controller sometimes marked as "disconnected by peer" - #2631: SNMP Set PVD5840 params out1/assign - out4/assign fails - #2646: APPolo Server identifies backup jobs as SmartUpdate jobs mistakenly ===================================================================== LYNX APPolo | Control Server - RELEASE 6.3.0 (build 562, Jun 7 2013) COMPATIBLE with LYNX APPolo | Control GUI 6.3.0 and above ------------------------------------------------ Fixes in Server functionality - #2465: C2-assisted backup occasionally fails in state WaitingForInitialData - #2555: Restore reports success even though it failed - #2601: Rescanning PVD5840 during restore - restore incomplete and reported as successful - #2615: RCP5044 panel does not evaluate button state conditions during start-up - Improved power-up scan of remote rack controllers Device specific features - Added UI support for PDM 5380 O - Added UI support for PVD 5810 - Added UI support for PVD 5800 ===================================================================== LYNX APPolo | Control Server - RELEASE 6.2.1 (build 553, Apr 10 2013) COMPATIBLE with LYNX APPolo | Control GUI 6.2.0 and above ------------------------------------------------ Fixes in Server functionality - #2484: Logfile does not show UTF-8 encoded user name and comment of SmartUpdate jobs correctly - #2586: RemoteIF: Connection reset by the client can crash the APPolo server Device specific features - Added UI support for RCT 5023-G ===================================================================== LYNX APPolo | Control Server - RELEASE 6.2.0 (build 547, Feb 21 2013) COMPATIBLE with LYNX APPolo | Control GUI 6.2.0 and above ------------------------------------------------ Enhancements in Server functionality - Added DHCP switch to server WebIF on Colibri Fixes in Server functionality - #1615: APPolo Server WebIF: There's no possibility for a customer to see the history file - #1665: RCT5031 WebIF fails when deleting the active server version - #1817: Web IF: Show info "activating... please wait..." after user has confirm SW activation - #2180: APPolo Server 5.0.0 and later: WebIF looks ugly in Internet Explorer 6 - #2194: Embedded-Server WebIF: version downgrade 5.0.2 -> 4.9.0 would not restart server OK - #2197: Embedded-Server WebIF: activating version 5.0.2 does not start new look&feel - #2361: APPolo GUI 5.1.0: Simulation sends wrong address if there are active network connections - #2374: RemoteIF: Warning about rejected client connection not notified to the client - #2407: RCT5031 WebIF Log-Analyzer: show serial number, collapse duplicate entries - #2454: bluBox shows fan status as missing - #2463: server WebIF: Logfile analyzer does not work - #2498: APPolo Server: RemoteIF List-Subscription on Slots (per Frame) does not update when last device disappears - #2501: Colibri Linux: /etc/resolv.conv disturbs network communication - #2510: RCT 5023-S: Controller does not report the correct IP adress of the hosted server - #2512: APPolo Server: Colibri does not have a correct IP-Address when running in DHCP-mode - #2515: C3-Server RemoteIF: Some parameters not listed in initial ";P;;*;" command - Fixed faulty timeout error after SmartUpdate of rack controllers Device specific features - Added UI support for PVD 5840-DOW/UOW - Added UI support for PVD 5822-DOW/DOW - Added UI support for OTX 5840 - Added UI support for OTR 5840 - Added UI support for ORX 5840 - PVD5660 (SW label 530 and above): Added UI parameter for H-Flip control - Added UI support for PDM 5380 ===================================================================== LYNX APPolo | Control Server - RELEASE 6.1.2 (build 519, Sep 27 2012) COMPATIBLE with LYNX APPolo | Control GUI 6.1.0 and above ------------------------------------------------ Fixes in Server functionality - Fixed faulty timeout error after SmartUpdate of rack controllers - Event log shows updated devices as "updated" rather than "exchanged" or "removed" ===================================================================== LYNX APPolo | Control Server - RELEASE 6.1.1 (build 516, Sep 7 2012) COMPATIBLE with LYNX APPolo | Control GUI 6.1.0 and above ------------------------------------------------ Enhancements in Server functionality - Improved memory consumption of device UI parameters, Remote IF allows concurrent access to 20000 device parameters Fixes in Server functionality - Server attempts to reconnect attached rack controllers periodically if they were found offline before - SmartUpdate engine resumes data transfer if controller reports missing packets after presumably complete transfer - SmartUpdate engine does not change the state of finished items upon errors in other slots anymore - Restore of server root items saves the restored configuration variables to file immediately - #2462: RCT5030: XBoard server restarts if switching the crossbar within a connected OTX 5844 Device specific fixes & enhancements - PDM5289: Added UI support for Time Code Video Burn-In - #2385: GUI: highlight modified timing values (FlexCard, PDM52xx) - #2387: GUI (all converters): place link to configuration of DVITC reader into contect of converter - #2394: GUI (FlexCards): UserPresets managment buttons to be disabled while loading preset by GPI - #2456: PVD5840: Auto Aspect Ratio Parameters for Converter 4 controlling Converter 3 ===================================================================== LYNX APPolo | Control Server - RELEASE 6.1.0 (build 512, Aug 22 2012) COMPATIBLE with LYNX APPolo | Control GUI 6.1.0 and above ------------------------------------------------ Enhancements in Server functionality - Embedded Server in RCT5031 and RCT5023-S supports SmartUpdate, i.e. device firmware update over the network - Embedded Server accepts up to 256 rack attachments over UDP/IP Fixes in Server functionality - #2368: WebIF: Software "Install" Button to be renamed "Upload" - #2273: APPolo Server: New device with active Events does not report Events in logfile - #2291: APPolo Server: Security hole: (SNMP) passwords need to be stored in encrypted form - #2337: APPolo Server: Rack Fan Status does not report missing fan - #2363: RemoteIF: setting parameter to invalid string may shutdown application - #2403: WebIF: Restart of LNCP daemon after server activation missing Fixes in Panel Controller functionality - #2278: RCP5044: setting IP address through local UI does not set gateway Device specific fixes & enhancements - Added support for new LYNX product series "bluBox" - Added support for RCT5023 and RCT5023-S - PVD5840: Added Input to REF Tolerance Parameter - PVD and PIE devices: Added psf support and Segmented Frame format detection parameter - #2032: PIE delay setting behaves strange near terminal line count - #2401: PVD 5840: The SDTV ARC, Noise Reduction & Color Correction functions should always be visible - #2420: PDM5289: ATC-LTC deletion does not work in 625 - #2427: CDA5220: Audio mono gain sliders are swapped ================================================================== LYNX APPolo | Control Server - RELEASE 6.0.1 (build 499, May 4 2012) COMPATIBLE with LYNX APPolo | Control GUI 6.0.1 and above ------------------------------------------------ Fixes in Server functionality - Fixed memory leak in server side processing of device events Device specific fixes & enhancements - #2336: PDM5289: UIParams for old-style crossbar control: update of remoteIF - Added mono gain control for CDA5220 (SW label 269 and above) ===================================================================== LYNX APPolo | Control Server - RELEASE 6.0.0 (build 494, Apr 3 2012) COMPATIBLE with LYNX APPolo | Control GUI 6.0.0 and above ------------------------------------------------ Fixes in Server functionality - #2290: APPolo Server: SNMP community strings cannot be modified - #2296: BackupRestore: restoring PVD5806 with RCT5022 fails Device specific fixes & enhancements - Added UI support for PVD5822-DO/-UO/-D/-U - Added UI support for PVD5840-D/-U - Added UI support for RCT5022 - Added UI support for RPS5018 - Added GPI2 Control for PVD5840 (SW label 486 and above) - Added Fast Converter Delay Mode for CDX5624 (SW label 488 and above) - Added YCrCb Clipping Level control for FlexCard product family (SW label 489 and above) ===================================================================== LYNX APPolo | Control Server - RELEASE 5.1.1 (build 483, Jan 30 2012) COMPATIBLE with LYNX APPolo | Control GUI 5.1.0 and above ------------------------------------------------ Fixes in RCP functionality - #2102: RCP5000: Local server does not find any devices after operation with RCP5016 - #2274: RCP5044 / RCT5031: Device type detection is unreliable - #2275: RCP5044: The system start-up does not set the correct factory-default IP address - #2277: RCP5044: Menu does not allow navigation to connected server Device specific fixes & enhancements - Added UI support for RFR5041 - Added UI support for PVD5840-DO ===================================================================== LYNX APPolo | Control Server - RELEASE 5.1.0 (build 469, Dec 8 2011) COMPATIBLE with LYNX APPolo | Control GUI 5.1.0 and above ------------------------------------------------ Enhancements in Server functionality - Integrated SNMP agent supporting get/set access to all device parameters (requires software option OC_RSLRCTI or OC_RSLSNMP in the RCT503x MasterController) - Device parameters for user preset control are accessible over the Remote Control interface Fixes in RCP functionality - #2231: RCP displays "Base" when navigating back from offline devices Device specific fixes & enhancements - Added UI support for PVD5840-UO - Added UI support for DVA5718L, DVA5724 and DVA5760L - Added meta data control for PDM5289-D ===================================================================== LYNX APPolo | Control Server - RELEASE 5.0.3 (build 458, Sep 22 2011) COMPATIBLE with LYNX APPolo | Control GUI 5.0.0 and above ------------------------------------------------ Enhancements in Server functionality - Remote IF optionally sends notification after complete processing of wildcard parameter commands (enabled by config variable REMOTE_NOTIFY_CHILD_COMPLETION) Fixes in RCP functionality - #2190: RCP5000 with APPolo Server 5.0.2 cannot connect to remote servers ===================================================================== LYNX APPolo | Control Server - RELEASE 5.0.2 (build 451, Aug 3 2011) COMPATIBLE with LYNX APPolo | Control GUI 5.0.0 and above ------------------------------------------------ Device specific fixes & enhancements - Added UI support for PDM5289-D - PVD5660, PIE5610, PVD5806, PIE5810 (SW label 429 and above): Added UI support for embedding teletext into alternating progressive frames ===================================================================== LYNX APPolo | Control Server - RELEASE 5.0.1 (build 442, Jun 21 2011) COMPATIBLE with LYNX APPolo | Control GUI 5.0.0 and above ------------------------------------------------ Enhancements in RCP functionality - Added support for RCP5044 Remote Control Panel - Added start-up detection of RCP5016 connected to RCP5044 Fixes in Server functionality - #1347: RemoteIF sends too many replies at once when handling wildcard commands - #2103: RCT5021: Fixed occasional loss of attachment to server - #2120: Old backup method fails with timeout at devices with multi-page flash - #2142: RCT 5021 takes to long to reconnect to Appolo Server using ethernet connection Device specific fixes & enhancements - Added UI support for PVD5630-O ===================================================================== LYNX APPolo | Control Server - RELEASE 5.0.0 (build 432, Mar 21 2011) COMPATIBLE with LYNX APPolo | Control GUI 5.0.0 and above ------------------------------------------------ Enhancements in RCP functionality - Hierarchical navigation through device tree and parameters in standard navigation mode Enhancements in web interface - Face-lifting of the web interface - New integrated logfile analyzer Enhancements in RemoteIF functionality - New command key "DN" allows reading the display names of device parameters - Updated the RemoteIF protocol specification to version 1.7 Fixes in Server functionality - #2113: RCT5031: FTP daemon rejects client connections Device specific fixes & enhancements - Added UI support (RCP / RemoteIF) for PVD5660-O - #2053: PVD5630, PVD5612, PVD5812, PVD5806: Corrected the list of selection values in UI parameter AudioDolbyETiming - PDX5362: extended range of audio gain (enabled by config switch PDX5362_AUDIO_GAIN_EXTENDED_RANGE) - OET1540: Added UI parameter "EthernetDuplexMode" - OTX5844, OTR5842, DVO5810, DVO5820: Added UI parameter AutoDisableOpticalOutput =============================================================== LYNX Device Controller - RELEASE 4.9.0 (build 425, Feb 2 2011) COMPATIBLE with client software 4.9.0 and above (c3_local / RCP) ------------------------------------------------ Enhancements in RCP Panel Controller functionality - Added panel lock feature (custom navigation mode) - Added button state changes based on RemoteIF parameter subscriptions and device presence monitoring (custom navigation mode) - New sub-menu scrolling (custom navigation mode, to be enabled in the panel config files) Fixes in RCP Panel Controller functionality - #1030: RCP configuration is not directly active - #1124: Locate function displayed on panel - #1859: Cannot delete last server IP adress in WebIF (Panel Connections) - #1902: Confirmation Question for parameter in submenu is applied to entering the menu - #2005: Panel configuration uploaded in Web IF cannot be downloaded to RCP config editor Enhancements in Device Controller functionality - Added support for configuring network settings and admin/ctrl passwords from the "Network Component Configuration" dialog in the LYNX Desktop Controller - Insertion and removal of SFP modules in optical backpanels are stated in the application logfile Fixes in Device Controller functionality - #1976: Admin login to RCT5031 not anymore possible after editing users from the GUI - #2052: c3_server on RCT5031 does not show the configured IP gateway in the server logfile Device specific fixes & enhancements - Added UI support (RCP / RemoteIF) for DVD5830 - Added UI support (RCP / RemoteIF) for OTX5844 - Added UI support (RCP / RemoteIF) for ORX5804 - Added UI support (RCP / RemoteIF) for OTR5842 - #1998 PVD5612, PVD5812: Added UI parameter "SyncMode*" - #1999 PVD5612, PVD5812: Removed unsupported UI parameters for Private ARC - #2000 PVD5612, PVD5812: Removed unsupported UI parameters for meta-data handling - #2028 PTG5610: Loading pattern list in the GUI of the PTG 5610 sometimes fails - DVO5810, DVO5820: Added detection of SFP-Modules - PIE5610, PIE5810, PVD5660, PVD5806 (SW label 403 and above): Added UI parameter "Conv3/LockImgConvSettings" for prevention of automatic reconfiguration of output format for Scaler-3 (HiQ). - PVD5660 (SW label 425 and above): Added support for OP47 field inversion - SVD5842: Added UI parameters "FallbackInputX" for fallback functionality =============================================================== LYNX Device Controller - RELEASE 4.8.2 (build 405, Nov 4 2010) COMPATIBLE with client software 4.8.0 and above (c3_local / RCP) ------------------------------------------------ Fixes in Device Controller functionality - #1986: RemoteIF: locking a device does not send out Properties Subscription Update Device specific fixes & enhancements - PVD5612, PVD5630, PVD5660, PVD5812 (SW label 401 and above): - Added UI parameter "ASCAResourceAssign" - PDL5600, PIE5610, PIE5810, PVD5612, PVD5630, PVD5660, PVD5806, PVD5812 (SW label 402 and above): - Added controls for ANC line selection - Added selection "Psf to P" to UI parameter "OutX/ModifyPsF" =============================================================== LYNX Device Controller - RELEASE 4.8.1 (build 402, Oct 19 2010) COMPATIBLE with client software 4.8.0 and above (c3_local / RCP) ------------------------------------------------ Fixes in Device Controller functionality - #1930: User can enter any new key and value into server configuration panel - #1936: Changed remote protocol version to 1.6 - #1950: Server does not start after downgrade from 4.8.0 to 4.7.4 - #1953: RemoteIF: addressing non-existent device falls back to wrong device - #1954: Device GUI appears to be detached from HW Device specific fixes & enhancements - #1925: RFR 5004: Event Tab Parameter "one RPS unit missing" marked red - #1935: Fixed support of Option "Color-Correction" for PVD5660 (SW label 394 and above) - PVD5660: Added UI parameter OutX/ModifyPsF for "P to PsF" conversion at SDI output (SW label 396 and above) - Added UI support (RCP / RemoteIF) for SVD5842 - Added UI support (RCP / RemoteIF) for PVD5806-O - Added UI support (RCP / RemoteIF) for PVD5810-O - Added UI support (RCP / RemoteIF) for PVD5812-O =============================================================== LYNX Device Controller - RELEASE 4.8.0 (build 395, Aug 25 2010) COMPATIBLE with client software 4.8.0 and above (c3_local / RCP) ------------------------------------------------ Enhancements in Device Controller functionality - Added attach functionality for LYNX network devices Fixes in Device Controller functionality - #1445: RCT5030: join SW-options SNMPTraps and LYNXRemoteControl - Remote IF: New parameter type "MultiSelection" (cf. LYNX Remote Protocol Specification v1.6 for details) Device specific fixes & enhancements - Added UI parameters for PVD5812 without 3GBit standards - PDM5288: Added UI parameters for audio content detection (SW label 386 and above) - PDM5288: Added UI parameters for 3GBit standards (SW label 387 and above) - DVO5810 and DVO5820: Added UI parameter SfpModuleType - #1901: New block diagram for DVO5810 =============================================================== LYNX Device Controller - RELEASE 4.7.5 (build 386, Jun 28 2010) COMPATIBLE with client software 4.7.1 and above (c3_local / RCP) ------------------------------------------------ Fixes in backup/restore engine - #1830: Device display names with special characters cannot be backed up - #1873: Importing a Backup Set (with devices) from a RCT5030 into a RCT 5031 does not work - #1875: GUI 4.7.3 Backup/Restore Problem with equally named files Device specific fixes & enhancements - PIE5610: Added UI parameters for Color-Correction - Added UI parameters for DVO5810 and DVO5820 - Added UI parameters for DVD5810-R and DVD5820-R - DVD5610 and DVD5620: Fixed incorrect SDI format detection on SDI input - PVD5660-0: Added UI parameters Conv3/Detail/Level and Conv3/Detail/Threshold =============================================================== LYNX Device Controller - RELEASE 4.7.4 (build 384, Jun 15 2010) COMPATIBLE with client software 4.7.1 and above (c3_local / RCP) ------------------------------------------------ Enhancements & fixes in Device Controller functionality - Fast backup/restore of all devices with a configuration block spanning over multiple flash page (requires SW label 377 or above in rack controller RCT 5020/21/30/31) Fixes for RCP5000 panel - #1888: RCP5000 with server release 4.7.3: Web IF cannot display panel configuration page Device specific enhancements - PVD5660-1 (BS5613-A): - Removed SW option "Down Converter" for devices with SW label 376 and above - Reduced UI parameters for non-existing functions in devices with SW label 376 and above (no Lynx scaler, 1 x Dolby Framesync, 1 x SDI input, 2 x SDI output, only WSS meta data) - PVD5660: Added UI parameters OutX/PrivateARC_GPION and OutX/PrivateARC_GPIOFF (only if enabled by config variable SHOW_PRIVATE_ARC_CONTROLS) =============================================================== LYNX Device Controller - RELEASE 4.7.3 (build 380, May 27 2010) COMPATIBLE with client software 4.7.1 and above (c3_local / RCP) ------------------------------------------------ Enhancements & fixes in Device Controller functionality - Improved connection management with BFE-BD51 panel, workaround for "screensaver" problem - Fixed #1856: RCT5030: Hyper Terminal does not work Device specific enhancements - Added UI support (RCP / RemoteIF) for PDM5288 - Added UI support (RCP / RemoteIF) for DVD5810 and DVD5820 - PIE5610: New UI parameter EnableBits - PVD5660: New UI parameters StatusFormatReactOnChange, StatusFormatReactOnLoss, SnapToReferenceFrameLength - #1496: PDX 3362: Added missing block diagram - #1720: PDX 3362: Added control for "phase aligned demux" - #1664: PVD 5612: Removed meaningless mode "Fixed Processing Time" =============================================================== LYNX Device Controller - RELEASE 4.7.2 (build 372, Mar 31 2010) COMPATIBLE with client software 4.7.1 and above (c3_local / RCP) ------------------------------------------------ Fixes backup/restore - Improved data conversion when restoring backups sets from older SW labels into updated PVD56xx/PDL5600/PIE5610 - Corrected handling of excluded backup job items - #1813: Corrected flash data verification in restore of RCT503x - #1830: Device display names with special characters cannot be backed up Fixes remote IF - #1818: Added config variable REMOTE_LOG_FILTER: Regular expression filter for suppressing certain remote log messages, default value ";(authentication|appVersionLong|uptime);" Fixes RCP - Network settings (IP address and netmask) can be modified in RCP configuration menu - #1821: Update of parameters happens only if parameters are currently in display - #1823: Need backward compatibility to older versions of configuration data model Device specific fixes and enhancements - Added UI parameters for DVD5810 and DVD5820 - PVD5660/PIE5610: Added UI parameters for "Closed Caption" and "Time Code" (SW label 368 and above) - PVD56xx/PIE5610: Added selection "Test Pattern" to UI parameters Out(x)/FreezeMode - PVD56xx: Fixed UI parameters Conv1/AspectInSelect, Conv2/AspectInSelect (SW label 322 and above) - #1661: GUI PIE5610/PVD5660: Hi-Q scaler output format list is not correct for some input standards =============================================================== LYNX Device Controller - RELEASE 4.7.1 (build 366, Feb 8 2010) COMPATIBLE with client software 4.7.1 and above (c3_local / RCP) ------------------------------------------------ Enhancements RemoteIF - A set of new base parameters facilitates remote-controlled backup & restore - Read/property requests to uninitialized device parameters are answered after having received the requested data from the device hardware Fixes B&R engine - Fixed device type mismatch in B&R of combo devices - Added B&R support for simulated devices with multi-page flash - Improved resend mechanism for unreplied write messages to a device - Restore of PTGx610 "Testor" is finalized by triggering a device reset Fixes RCP - #776: RCP5000 serial number cannot easily be assigned - #1031: RCT 5030/5020 parameters are not reachable by the RCP - #1121: Loading time takes too long - #1770: RCP5000 terminal mode not available at RS232 port - Automatic server login with name and password provided in panel configuration file - Default server login as if panel configuration file doesn't contain login data - Avoid early instantiation of all device parameters at once when entering a device node in a user-defined panel configuraiton Fixes RCT5031 - #1757: RCT5031 does not terminate DHCP client while setting a static IP address - Updated support for control of BFE BDxx panel with software version 1.8.6 - Detection of IRQ storm on UART in Linux kernel and UART re-initialization in server SW Device specific fixes - #1654: PVD56xx: mono control leftovers (red circles) are sometimes still displayed in the audio crossbar by mistake - #1722: Mono Crossbar control does not allow the selection of all possible crosspoints - #1766: PVD56xx: Update of UI parameter "OutX/DelayMs" calculation does not work - CDX3624: New selection value "RGB" for UI parameter "aVid/Out1" (SW label 345 and above) - PVD56xx: New UI parameter "OutX/DelayMode" - PVD56xx: Removed selections "Freeze Feeld1", "Freeze Feeld2" from UI parameter "OutX/IfNoInput" - New UI parameters for stereo XBar control in HD deembedder products (in addition to existing mono XBar control) Device specific fixes - #1654: PVD56xx: mono control leftovers (red circles) are sometimes still displayed in the audio crossbar by mistake - #1722: Mono Crossbar control does not allow the selection of all possible crosspoints - #1766: PVD56xx: Update of UI parameter "OutX/DelayMs" calculation does not work - CDX3624: New selection value "RGB" for UI parameter "aVid/Out1" (SW label 345 and above) - PVD56xx: New UI parameter "OutX/DelayMode" - PVD56xx: Removed selections "Freeze Feeld1", "Freeze Feeld2" from UI parameter "OutX/IfNoInput" =============================================================== LYNX Device Controller - RELEASE 4.6.7 (build 347, Nov 19 2009) COMPATIBLE with client software 4.6.0 and above (c3_local / RCP) ------------------------------------------------ New Features - PMX5264, PMX5268, PMX3362: Added parameter control for Channel Status Block Transparency in SDTV (release 344 and higher) - PMX5364, PMX5264, PMX5268, PMX3362: Added parameter controls for H- and V-Blanking (release 338 and higher) - PMX5364, PMX5264, PMX5268, PDX5264, PDX5268, PMX3264, PMX3362, PDX3264, PDX3362: Added parameter control for "Fast Genlock" (release 338 and higher) - Added GUI for CDX5025 ------------------------------------------------ Fixes - #1692: Combo-Devices do not update UI parameters on spontaneous change in device - #1758: DVA5710/20: The maximum value of UI parameters Equ will change spontaneously - #1763: Backup fails after cancelled restore - #1764: Rack controller does not re-activate hotsync after cancelled restore operation =============================================================== LYNX Device Controller - RELEASE 4.6.6 (build 341, Oct 5 2009) COMPATIBLE with client software 4.6.0 and above (c3_local / RCP) ------------------------------------------------ Fixes in B&R engine - Added correction of server names in backup jobs (handle potential changes of the server IP address) - Changed default value of BACKUP_MAX_ITEMS_PER_STACK to 1 - COLLECT_MAINTENANCE_INFORMATION enables verbose backup logging - Disable stack hotsync during B&R regardless of the setting read from the controller - Open write requests are discarded before starting backup (enabling start of backup after previous failure) - Improved retransmission of write messages on rackbus (fixing former timeout failures during restore) Fixes in user preset handling - All device registers & parameter values cached in the server are invalidated when loading/activating a user preset - Parameter changes (e.g. from remote IF) are deferred until the invalidated data receives a server update - Changed UI parameter "Presets_active" to read-only Fixes in web IF - #549: RCT5031 Web IF: Changing SW appears possible when logged in as - #1699: RCT5031 Web IF: Making IP settings on does not work - #1729: RCT5031 Web IF: Server SW cannot be updated on COLIBRI_332 Device specific fixes - #1658: Pairing of two PAD5212 within a Stack did not work - DVD560x: Added support for new video standards (device SW label 331 and above) - PVD56xx etc: Corrected register/selection mapping of UI parameter Out*/CSCMode =============================================================== LYNX Device Controller - RELEASE 4.6.5 (build 332, Aug 4 2009) COMPATIBLE with client software 4.6.0 and above (c3_local / RCP) ------------------------------------------------ Fixes B&R - #1685: B&R: Restore times out on DVA5710 and other devices rebooting very fast - Hotsync of RCT5020/21/30/31 is temporarily disabled during B&R operation - Backup of root device (server IP address in device tree) contains all confiuration variables having non-default values - Force read-back & verification of restored flash if the device does not confirm the write message - Added COM port adjustment in display name restoration between RCT5030 and RCT5031 Fixes in UI Layer & RemoteIF - #1669: GUI 4.6.0: Writing FactoryReset on RemoteIF can invalidate device type - Removed assignment of working register 0x00 from UI parameters using special methods for reading and writing Device Specific Fixes - RCT5010 supports B&R =============================================================== LYNX Device Controller - RELEASE 4.6.4 (build 331, Jul 24 2009) COMPATIBLE with client software 4.6.0 and above (c3_local / RCP) ------------------------------------------------ Fixes B&R - Further improved stability Device Specific Fixes - PVD5630: Corrected register mapping of parameter Conv(x)/AspectInSelect =============================================================== LYNX Device Controller - RELEASE 4.6.3 (build 330, Jul 16 2009) COMPATIBLE with client software 4.6.0 and above (c3_local / RCP) ------------------------------------------------ Fixes B&R - #1518: Backup can lead to server shutdown - #1635: Backup fails with error "no data" - Generally improved stability - Improved behaviour when GUI to server connection is lost during backup/restore - Problem of not selectable backup jobs is solved Fixes Remote IF - Remote IF is opened after completion of start-up auto-initialization - #1456: writing to some read-only parameters isn't blocked - #1655: c3_server 4.6.2 and older: Unsubscribe commands are not executed - Improved stability with high traffic on RIF Fixes Front Connector Terminal - #1616: RCT5031: serial terminal (front-connector) with ECHO on Device Specific Fixes - #1650: PVD5660 Testpattern "follow last input" doesn't work - PVD5660/PVD5630-1/PVD5612 release 313: New UI parameter DelayPulseAssign - PVD5660/PVD5630-1/PVD5612 release 326: New UI parameters Out(x)/ClipHeadroom, Out(x)/FixedProcTime - PIE5612/PDL5600 release 326: New UI parameter Out(x)/ClipHeadroom =============================================================== LYNX Device Controller - RELEASE 4.6.2 (build 327, Jun 25 2009) COMPATIBLE with client software 4.6.0 and above (c3_local / RCP) ------------------------------------------------ Fixes - general stability improvements recommended version to improve stability with network connectivity =============================================================== LYNX Device Controller - RELEASE 4.6.1 (build 326, Jun 23 2009) COMPATIBLE with client software 4.6.0 and above (c3_local / RCP) ------------------------------------------------ New Features - added support for next generation CDX5624 with 4 AES outputs and RGB ------------------------------------------------ Fixes - bug #1638: improved watchdog to recover from stalled server ============================================================== LYNX Device Controller - RELEASE 4.6.0 (build 324, Jun 8 2009) COMPATIBLE with client software 4.6.0 and above (c3_local / RCP) ------------------------------------------------ New Features - PVD5660: added controls for AFD, WSS and VI (release 322 and higher) - PVD5660: supports "Dolby E" detection (release 322 and higher) - PVD5660: added "DolbyE" frame sync paths (release 322 and higher) =============================================================== LYNX Device Controller - RELEASE 4.5.4 (build 322, May 22 2009) COMPATIBLE with client software 4.5.0 and above (c3_local / RCP) ------------------------------------------------ New Features - PDX3362, PDX526x: New UI parameter "FastGenlock" enables faster SDI and audio outputs after a disturbance / reconnection of the SDI input ------------------------------------------------ Fixes - bug #1619: Fixed asynchronous client-server communication to ensure that parameter changes are sent to the devcie registers in the correct order =============================================================== LYNX Device Controller - RELEASE 4.5.3 (build 318, Apr 28 2009) COMPATIBLE with client software 4.5.0 and above (c3_local / RCP) ------------------------------------------------ New Features - RCT5031: New rack controller (successor of RCT5030) ------------------------------------------------ Fixes - Remote IF: Added periodic retries for channel initialization in case of initialization failure Fixed memory leak in device UI cache, causing slow-down of remote control after several hours - bug #837: Rounding correction of float-type UI parameters (further enhancement) =============================================================== LYNX Device Controller - RELEASE 4.5.2 (build 315, Apr 8 2009) COMPATIBLE with client software 4.5.0 and above (c3_local / RCP) ------------------------------------------------ New Features - UI parameter 'Freeze Mode' offers option 'Force Freeze' if new config switch PVD56xx_FORCE_FREEZE is TRUE - Config switch DEBUG_CREATE_PVD_SCALER_PARAMS leads to generation of UI parameters for direct control of parameters for LYNX scaler (and implicitly to generation of separate page in GUI with appropriate sliders) - Changed remote protocol to include step width in the properties of float parameters ------------------------------------------------ Fixes - PMX5364: Fixed UI parameter error that 24 bit embedding could not be selected for some HD standards - bug #1600 + #1601: Web IF and RCP can talk to local c3_server again - bug #837: Corrected rounding error between user values and register values of float parameters - Modified remoteIFTCP to prevent deadlock while handling partial remote commands in the input buffer - bug #1604: PC module on RCT503x reboots after watchdog update to get the system into a clean state - Changed CORBA initialization to use one single TCP connection - Some minor improvements in backup/restore engine =============================================================== LYNX Device Controller - RELEASE 4.5.1 (build 310, Mar 2 2009) COMPATIBLE with client software 4.5.0 and above (c3_local / RCP) ------------------------------------------------ New Features - Backup & restore: - Added support for CAD5320, CAD5321, CDX5024 and DVD5002 - Backup jobs accept extended character set incl. German umlaut etc. =============================================================== LYNX Device Controller - RELEASE 4.5.0 (build 305, Jan 28 2009) COMPATIBLE with client software 4.5.0 and above (c3_local / RCP) ------------------------------------------------ New Features - Reworked backup & restore functionality including support for PVD5660 - LYNX Device Watchdog: Activate updated watchdog without rebooting the entire controller =============================================================== LYNX Device Controller - RELEASE 4.4.0 (build 229, Dec 1 2008) COMPATIBLE with client software 4.4.0 and above (c3_local / RCP) ------------------------------------------------ RCT5030 FEATURES RCP5000 FEATURES - Added User Interface for PMX5362 and PMX5364 SD/HD Analog audio Multiplexer ------------------------------------------------ Fixes - Remote IF: Fixed bugs in the replies to remote commands 'L' and 'P' that have beed introduced in BETA 4.4.0 - Rackbus message dispatcher: Fixed problem of occasional c3_server hangup due to interlocking of 2 threads waiting for each other =============================================================== LYNX Device Controller - BETA 4.4.0 (build 228, Oct 31 2008) COMPATIBLE with client software 4.4.0 and above (c3_local / RCP) ------------------------------------------------ RCT5030 FEATURES RCP5000 FEATURES - Added User Interface for PDL5600 Dual SD/HD Programmable Video Delay Line - Added User Interface for PAR5610 Aspect Ratio Converter with Optional UP/DOWN/CROSS conversion - PDX3264: added control for "Phase Aligned Deembedding" (release 274 and up) - PVD5660: audio group status detection (release 275 and up) - Automatic initialisation of device UI cache facititating faster access to the device parameters via remote IF =============================================================== LYNX Device Controller - RELEASE 4.3.1 (build 226, Oct 7 2008) COMPATIBLE with client software 4.3.1 and above (c3_local / RCP) ------------------------------------------------ RCP5000 FEATURES - general performance improvements of remote-control interface ------------------------------------------------ RCP5000 Fixes - fixed bug #1348 In release 4.3.0 the panel navigation did not return from the device parameter level to the main navigation level. =============================================================== LYNX Device Controller - RELEASE 4.3.0 (build 223, Sep 8 2008) COMPATIBLE with client software 4.3.0 and above (c3_local / RCP) ------------------------------------------------ RCT5030 FEATURES - Added TCP/IP based remote-control interface - PVD5630 UI: added controls for "Group-Deletion" functionality (release 257) - PVD5630 UI: added controls for "Phase aligned deembedding" functionality (release 257) - PVD5660 UI: added controls for "Group-Deletion" functionality - added support for next-generation CDA5011 User Interface (board type BS5010_05) =============================================================== LYNX Device Controller - BETA 4.3.0 (build 222, Aug 5 2008) COMPATIBLE with client software 4.3.0 and above (c3_local / RCP) ------------------------------------------------ RCT5030 FEATURES RCP5000 FEATURES - Added User Interface for PVD5660 (HD/SD Framesynchronizer with Aspect Ration Converter, Optional Up/Down Converter) - Added User Interface for DVD5426 (HD/SD SDI/ASI distribution amplifier with reclocking / inversion) =============================================================== LYNX Device Controller - RELEASE 4.2.0 (build 218, Mai 26 2008) COMPATIBLE with client software 4.1.5 and above (c3_local / RCP). ------------------------------------------------ RCP5000 Fixes - fixed bug #815 Under certain conditions, and after a very long time (~2 weeks) with no human interaction whatsoever, rotating a rotation knob would not yield any reaction before the same knob has been pressed once. =============================================================== LYNX Device Controller - RELEASE 4.1.3 (build 215, Feb 26 2008) COMPATIBLE with client software 4.1.0 and above (c3_local / RCP). ------------------------------------------------ RCT5030 FEATURES - added configuration variable OPERATE_LOCAL_UI_AS_USER If modified from the (empty) default, all local UIs (user interfaces - such as SNMP, RemoteIF, BD51-Panel, ...) operate as the specified user (from RCT5030's user database). This is relevant if you intend to apply user-access-control to such a local user interface. - Added User Interface for PTG5610: (HD/SD Digital Audio&Video Testsignal Generator) - Added User Interface for DVD3601: (HD/SD Downconverter) ------------------------------------------------ RCP5000 Fixes - fixed bug #1130 Under certain conditions, adding a LYNX server through the RCP5000 Web-Interface would not become effective. - fixed bug #1135: UI of CAD5112: Testpattern-controls did not work for devices with subversion > 0x30 =============================================================== LYNX Device Controller - RELEASE 4.1.2 (build 214, Jan 31 2008) COMPATIBLE with client software 4.0.0 and above (c3_local / RCP). ------------------------------------------------ RCP5000 FEATURES - Added support for custom panel configurations (per XML-file) - Improved re-connection behaviour to optional RCP5016 extension panel. ------------------------------------------------ RCT5030 FEATURES - PTG3610: adapted for support of latest Testor Version 234 - BD51 Panel Server Added functionality to act as panel server for BFE BD51 network panel. The BD51 can be configured to control a signal crossbar from one of the connected LYNX Devices. This functionality needs to be configured using these config-variables: PANEL_BDXX_CONNECT - IP-address of BFE-BD51 panel to be controlled by this server. PANEL_BDXX_TO_CONTROL_DEVICE - Complete LYNX Address of controlled device PANEL_BDXX_TO_CONTROL_UIPARAMS - RegExp matching the collection of controlled UIParams Optional additional controls to further adjust behaviour of panel server PANEL_BDXX_TO_REPLACE_STRINGS - possible user labels for individual buttons PANEL_BDXX_COLORS - possible user colors for individual button states For detailed information on and modification of these parameters: see Web-Interface of RCT5030. =============================================================== LYNX Device Controller - RELEASE 4.1.0 (build 212, Now 16 2007) COMPATIBLE with client software 4.0.0 and above (c3_local / RCP). ------------------------------------------------ RCP5000 FEATURES - Added User Interface for SVD5612 (HD Change Over Switch) - Added User Interface for PDX3264 (HD/SD Audio Deembedder) - Added User Interface for PMX3264 (HD/SD Audio Embedder) - Added User Interface for PMX3362 (HD/SD Analog Audio Embedder) - PVD5630 UI: add controls to couple SDI-Out2/3 to SDI-Out1 (sync all settings) - PDX3010 UI: add controls to set PAL M/N video output format - PMX5262/PMX5264/PMX3262/PMX3264 UI add control for optional "Auto-Black" (generate black output if no input signal) ------------------------------------------------ RCP5000 Fixes - fix bug #1013: removed void controls "Swap left/right" from CDX3624 UI - fix bug #1045: UI of RCT5030: UIParameter "Alarm1/2" corrected settings "Minor" and "Major" - RCT5030 UI: Parameter "Alarm1/2" corrected settings "Minor" and "Major" - Backup/Restore: Fix instability issues with restore in larger systems. =============================================================== LYNX Device Controller - RELEASE 4.0.0 (build 210, Oct 24 2007) COMPATIBLE with client software 4.0.0 and above (c3_local / RCP). ------------------------------------------------ RCP5000 FEATURES - Support new User-Access Functionality: With this version, the RCP5000 will respect user-access restrictions that have been specified in the RCT5030. The restrictions are specified using the LYNX-GUI and stored in the RCT5030 server (RELEASE 3.12.1 or higher). The RCP5000 will respect those restrictions, i.e. it will present a parameter as read-only if so specified for the current user - UI of SVD5012: add support for enhanced GPI latch mode settings (as of device version 208) - UI of PVD5610/PVD5630: added support for Audio-Delay settings - Adapted User Interface for PTG3610 Testor (new firmware 205 and above) - Added server support (list of test-patterns) for the new PTG3610 Testor (new firmware 205 and above) =============================================================== LYNX Device Controller - RELEASE 3.12.2 (build 206, Aug 10 2007) LYNX Device Controller - RELEASE 3.12.1 (build 205, Aug 7 2007) COMPATIBLE with client software 3.12.0 and above (c3_local / RCP). ------------------------------------------------ RCP5000 FEATURES - UI PVD56xx added support for H-/V- Transparency settings ------------------------------------------------ RCT5030 FEATURES - support the UserAccess Control functionality Access to this feature is possible only with appropriate software license and LYNX-GUI application 4.0.0 or higher. ------------------------------------------------ RCT5030 Fixes - fixed bug #953 PDX3212: GUI status GREEN while module status RED - UI of CAD51xx: corrected signal presence status display =============================================================== LYNX Device Controller - RELEASE 3.11.6 (build 203, Jul 13 2007) COMPATIBLE with client software 3.11.0 and above (c3_local / RCP). New Watchdog 3.0.3 with configurable parameters. See documentation of parameters WATCHDOG_TIMEOUT and WATCHDOG_GRACE =============================================================== LYNX Device Controller - RELEASE 3.11.5 (build 202, Jun 25 2007) LYNX Device Controller - RELEASE 3.11.4 (build 201, Jun 19 2007) COMPATIBLE with client software 3.11.0 and above (c3_local / RCP). ------------------------------------------------ RCT5030 Fixes - fixed bug: devices were detected as "lost" too quickly in the presence of usual commuication disturbances. - significant speed-up when accessing a device from any UI (RemoteIF / RCP5000) =============================================================== LYNX Device Controller - RELEASE 3.11.3 (build 200, Jun 18 2007) COMPATIBLE with client software 3.11.0 and above (c3_local / RCP). ------------------------------------------------ RCP5000 FEATURES - UI support for new generation of CDA3220 - PVD5005/PVD5010/CMX5112 UI: added control for audiodelay functionality added controls for "Sample Rate Conversion" - Added control for "group deletion" functionality" to UI of PVD5010 - PVD5630 UI: added (checkbox) controls for 20/24 Bit Audio conversion - PVD56xx UI: add scaler control for ARC functionality (requires P_VD_CONV option in PVD56xx) - Added User Interface for PVD5600 (Single-Input HDTV Framesync with optional image converter) - Added User Interface for PVD5610 (Single-Input HDTV Framesync with optional image converter and audio processing) - Added User Interface for PVD5620 (Dual-Input HDTV Framesync with optional image converters) - Added User Interface for PMX5262 (Dual AES HDTV Embedder) - Added User Interface for PMX5264 (Quad AES HDTV Embedder) - Added User Interface for PDX5362 (HD/SD Analog Audio Deembedder) - Added User Interface for DVA5720 (Dual Analog Video Distribution Amplifier, HDTV capable) - Added User Interface for DVA5710 (Single Analog Video Distribution Amplifier, HDTV capable) - Added User Interface for DVA3720 (Dual Analog Video Distribution Amplifier, HDTV capable) - Added User Interface for DVD5610 (Single HD-SDI Distribution Amplifier with optional reclocking) - Added User Interface for CDX5024C (Analog Audio Demultiplexer w/ Component Video Output) - Added supervision functionality for RFR5010 internal fans ------------------------------------------------ RCP5000 Fixes - fixed bug #912: UI of PVD5000/5005/5010: Saturation and Hue parameters would not influence the Cr component correctly. - fixed bug #909: UI of CAD5111 would set GainCr to MAX when moving the SAT (Saturation) control - reverted display of total delay for PVD Framesyncs to MilliSeconds ------------------------------------------------ RCT5030 Fixes - fixed bug: Netmask could not be set in the Web-Interface =============================================================== LYNX Device Controller - RELEASE 3.9.1 (build 194, May 23 2007) LYNX Device Controller - RELEASE 3.9.0 (build 193, Mar 2 2007) COMPATIBLE with client software 3.9.0 and above (c3_local / RCP). ------------------------------------------------ RCP5000 FEATURES - PVD5005/PVD5010 UI: added (boolean) controls for individual group deletion ------------------------------------------------ RCP5000 Fixes - fixed big #877 Removed "auto" from selection of possible Sample Rate Conversion modes. (not supported by device) - fixed bug #885: PDX3214 UI: could not control second deembedder group - fixed bug #886: CDX5624 UI: some parameters of the Video-DA-Conversion could not be controlled correctly. - fixed bug #897: DVD3620/DVD5620 UI: After a reset to factory defaults (in the device), it was possible that the UI did not display the correct cross-bar configuration. - fixed bug: PVD5000/PVD5005 UI: (variants without GPI) would display the current input as "SDI1" even if currently operating at "SDI2" ------------------------------------------------ RCT5030 Fixes - fixed bug #905: Server startup problem on mal-formatted Backup file. As a result the RCT5030 controller can appear to be completely locked (application not running). =============================================================== LYNX Device Controller - RELEASE 3.9.1 (build 194, May 23 2007) LYNX Device Controller - RELEASE 3.9.0 (build 193, Mar 2 2007) COMPATIBLE with client software 3.9.0 and above (c3_local / RCP). ------------------------------------------------ RCP5000 FEATURES - PVD5005/PVD5010 UI: added (boolean) controls for individual group deletion ------------------------------------------------ RCP5000 Fixes - fixed big #877 Removed "auto" from selection of possible Sample Rate Conversion modes. (not supported by device) - fixed bug #885: PDX3214 UI: could not control second deembedder group - fixed bug #886: CDX5624 UI: some parameters of the Video-DA-Conversion could not be controlled correctly. - fixed bug #897: DVD3620/DVD5620 UI: After a reset to factory defaults (in the device), it was possible that the UI did not display the correct cross-bar configuration. - fixed bug: PVD5000/PVD5005 UI: (variants without GPI) would display the current input as "SDI1" even if currently operating at "SDI2" ------------------------------------------------ RCT5030 Fixes - fixed bug #905: Server startup problem on mal-formatted Backup file. As a result the RCT5030 controller can appear to be completely locked (application not running). =============================================================== LYNX Device Controller - RELEASE 3.8.2 (build 192, Jan 15 2007) COMPATIBLE with client software 3.8.0 and above (c3_local / RCP). ------------------------------------------------ RCT5030 FEATURES - support for new generation of PMX3312 (type 06.09) ------------------------------------------------ RCP5000 FEATURES - UI support for new generation of PMX3312 (type 06.09) - UI support for CMX5112 (type 07.90 / 11.82) (SDI Framesync/Embedder with analog audio/video inputs) - UI support for CDX3610 (type 02.4e) (Multi-Format DownConverter with Analog Video output) - support Aperture correction controls in UI of DVD5602/DVD5604 ------------------------------------------------ RCP5000 Fixes - fix a bug that has been introduced in 3.7.5: under certain conditions, the standard navigation mode (if not modified from default behaviour) would not work reliably (rotating the navigation knob would not let you navigate as usual) - fixed bug #858 In the UI of PVD3010, PVD5000, PVD5005, PVD5010 the total delay (DelayUS) is changed from microsec to nanosec. =============================================================== LYNX Device Controller - RELEASE 3.7.5 (build 189, Dec 6 2006) COMPATIBLE with client software 3.7.0 and above (c3_local / RCP). ------------------------------------------------ RCP5000 FEATURES - Support for advanced configuration options in XML interface. =============================================================== LYNX Device Controller - RELEASE 3.7.4 (build 188, Nov 27 2006) COMPATIBLE with client software 3.7.0 and above (c3_local / RCP). ------------------------------------------------ RCT5030 IMPROVEMENTS - modified tty line discipline in Linux kernel to stabilize communication bandwidth. This helps avoiding unnecessarily long roundtrip-times for messages in large systems. ------------------------------------------------ RCP5000 FEATURES - UI support for new generation of PMX3212 (type 06.07) ------------------------------------------------ RCP5000 Fixes - fixed bug #827 The new UI of the CAD5121 and CAD5122 did not correctly implement dependency between "Contrast" and "Gain" for Channel 1. As an effect, the "Contrast" control would not be enabled in the UI as expected. - fixed bug #832 In the UI of PVD3010, the external AES connections would be shown as "enabled" if only option P_VD_MXDX was active. In fact, the external AES connections are active only on option P_VD_AP. The display in the UI has now been adapted accordingly. =============================================================== LYNX Device Controller - RELEASE 3.7.2 (build 186, 10.Oct.2006) COMPATIBLE with client software 3.7.0 and above (c3_local / RCP). ------------------------------------------------ RCT5030 FEATURES - Fixed weakness that could lead to slow communication in large installations (more than 5 RCT5020 controllers attached to RCT5030). ------------------------------------------------ RCP5000 FEATURES - Added User Interface for CAD5132 (type 03.8c) (Analog Video to SDI Converter w/ Frame Sync) - Added User Interface for DAA5321 (Dual-Channel Analog Audio DAmp with audio transformers) ------------------------------------------------ RCP5000 Fixes - fixed bug #802 UI of Video-DA-Converters (CDAxxxx) indicates a "missing reference" even for type variants that do not have a reference input. =============================================================== LYNX Device Controller - RELEASE 3.7.0 (build 184, 20.Sep.2006) COMPATIBLE with client software 3.7.0 and above (c3_local / RCP). ------------------------------------------------ RCT5030 FEATURES - Added support for several new GUI features, as released in PC-GUI RELEASE 3.7.0 (c3_local) =============================================================== LYNX Device Controller - RELEASE 3.6.8 (build 182, 17.Aug.2006) COMPATIBLE with client software 3.6.0 and above (c3_local / RCP). recommended client software: 3.6.8 or above. ------------------------------------------------ RCP5000 FEATURES - Added User Interface for PDX5212 (type 10) (Single channel SDI Distribution Amplifier) - Added Support for RCP5016 16-button Panel-Expansion, to be connected to RCP5000's rear SubD9 male connector. ------------------------------------------------ RCP5000 Fixes - fixed bug in UI of CDX5624: input signal standard 525 (SDTV) would not be displayed correctly. (device operation not limited, just display in UI was incorrect) =============================================================== LYNX Device Controller - RELEASE 3.6.1 (build 175, 13.Jul.2006) COMPATIBLE with client software 3.6.0 and above (c3_local / RCP). recommended client software: 3.6.1 or above. ------------------------------------------------ New Features - re-formatted the Logfile-entries about device-specific events to describe the reporting device (name and position) as human readable text. ------------------------------------------------ RCT5030 Fixes - fixed bug #760: Restore of multiple MiniModules fails with timeout. When restoring a backup set spawning multiple MiniModules (in a RTR3010, requires SW-license RSL_BR20 or RSL_BR30), then a certain percentage of items would always end up in a "restore failed on timeout" state. =============================================================== LYNX Device Controller - RELEASE 3.4.3 (build 172, 07.Jun.2006) COMPATIBLE with client software 3.4.0 and above (c3_local / RCP). recommended client software: 3.4.3 or above. ------------------------------------------------ RCP5000 Fixes - fixed bug: Under very rare circumstances it could happen, that a device is not shown in the RCP's list of devices although it has correctly been detected (as can be seen in the logfiles). This was a bug in the presentation logic. Fixed now. ------------------------------------------------ RCT5030 Fixes - removing a Device immediatley after it had just been detected by the system could lead to a situation where the device was never removed from the system. This has been fixed now. =============================================================== LYNX Device Controller - RELEASE 3.4.1 (build 170, 29.May.2006) COMPATIBLE with client software 3.4.0 and above (c3_local / RCP). ------------------------------------------------ RCT5030 FEATURES - Improved server side support for PTG3610 The client version (RCP5000/PC-GUI) 3.4.1 makes use of these improvements which results in a much more reliable remote control of the PTG3610 (Testor) ------------------------------------------------ RCP5000 FEATURES - Improvements to the Web-Interface: - changes to several parameters of the network configuration (page "System Settings") can be applied at once - server(s) can be explicitly restarted (page "System Settings") - Improved feedback in local RCP display if connection to a configured server could not be established. - Significantly reduce network traffic and server CPU load when logging into a remote server (RCT5030). This improvement is only available when client and server are both using version 3.4.1 (or above). ------------------------------------------------ RCP5000 Fixes - fixed bug #691: applying a change to the Panel Connections on the Web-Interface required the repeated specification of the server password. Changed to require the password only once. - fixed bug #734: modifying the Panel Connections from the Web-Interface required a restart of panel server to become effective. - fixed bug #744: Display of GAIN values off by 0.5 dB for devices DAA3320/DAA5320. - fixed bug: remove bogus entry "local COM ports" from list of available server connections in RCP frontpanel menu. - fixed bug #754: DVD5420: Master LED in GUI sometimes not correct. The Master LED color of a DVD5420 in the GUI/RCP5000 is sometimes not correct (according to master LED on the module) - fixed connection bug: when a server was restarted (e.g. because it was being re-configured) while a client was just logging in, the client (here: RCP5000) would appear to be locked for a long time (depending on number of devices at that server), before resuming normal operation. Now the client returns to the "disconnected" state within very short time, as expected. =============================================================== LYNX Device Controller - RELEASE 3.4.0 (build 167, 20.Apr.2006) COMPATIBLE with client software 3.4.0 and above (c3_local / RCP). ------------------------------------------------ RCT5030 FEATURES - Added server side support for CDX5624 (Multiformat down converter with analog Audio/Video outputs) =============================================================== LYNX Device Controller - RELEASE 3.3.5 (build 166, 12.Apr.2006) COMPATIBLE with client software 3.3.0 and above (c3_local / RCP). ------------------------------------------------ RCT5030 Fixes - fixed a few problems in the interpretation of remoteIF-commands that could lead to unresponded messages. =============================================================== LYNX Device Controller - RELEASE 3.3.4 (build 165, 05.Apr.2006) COMPATIBLE with client software 3.3.0 and above (c3_local / RCP). ------------------------------------------------ RCT5030 Fixes - fixed bug: in very large systems (many controllers and devices), accessing a large number of parameters (in different devices) at the same time can set the server into a high-traffic mode, not responding to any outside message anymore. This could lead the watchdog into restarting the server. =============================================================== LYNX Device Controller - RELEASE 3.3.3 (build 164, 03.Apr.2006) COMPATIBLE with client software 3.3.0 and above (c3_local / RCP). ------------------------------------------------ RCT5030 Fixes - fixed bug: Remote commands not recognized. depending on the formatting of the contained ASCII command string, certain remote-commands would not be recognized. =============================================================== LYNX Device Controller - RELEASE 3.3.2 (build 163, 31.Mar.2006) COMPATIBLE with client software 3.3.0 and above (c3_local / RCP). ------------------------------------------------ GENERAL general stability improvements, resulting in reduced number of automatic server clean-up/restart cycles. - reduced general CPU load - block remote access during startup phase - reduced total resource consumption or CORBA-ORB - watchdog is more tolerant in high-load situations - limit total size of logfiles (new config-variable LOGFILE_MAX_SIZE) ------------------------------------------------ RCT5030 FEATURES - The Backup of a Remote-Connection's top-level node also contains the user defined device-names of all hosted devices. ------------------------------------------------ RCT5030 Fixes - fixed bug #712: Backup sometimes not complete A Backup of one of the following device types would sometimes not be complete: CAD5121, CAD5122, PVD5010, CAD5135, CMX5110. =============================================================== LYNX Device Controller - RELEASE 3.3.0 (build 161, 03.Mar.2006) COMPATIBLE with client software 3.3.0 and above (c3_local / RCP). ------------------------------------------------ RCP5000 FEATURES - Added User Interface for DVD5000 (Single channel SDI Distribution Amplifier) - Added User Interface for DVD5010 (Single channel SDI Distribution Amplifier w/ reclocking) ------------------------------------------------ RCT5030 Fixes - fixed bug #708: Removing the RFR5011 from the system will not remove textual info from the GUI. - fixed bug #709: Starting Server on CDA5010 will influence Auto-Testsignal Starting the GUI on a system with CDA5010 boards will reset the Auto-Testsignal setting to factory default. - general server startup speed improvement =============================================================== LYNX Device Controller - RELEASE 3.1.2 (build 159, 22.Feb.2006) COMPATIBLE with client software 3.1.0 and above (c3_local / RCP). ------------------------------------------------ RCT5030 stability improvement - made sure that the RCT5030 watchdog process cannot be blocked by a device-server application with higher priority. This prevents from potential dead-locks of the complete system by such situations. ------------------------------------------------ RCP5000 Fixes - fixed bug #703: RCP5000 to PTG5010: cannot activate Sequence Patterns It is not possible to activate a Sequence Pattern in the PTG5010 using the RCP5000. All static patterns are selectable OK. =============================================================== LYNX Device Controller - RELEASE 3.1.1 (build 158, 14.Feb.2006) COMPATIBLE with client software 3.1.0 and above (c3_local / RCP). ------------------------------------------------ Fixes - fixed bug #701: Serial number of RCT3000 could not be read in GUI The GUI did not display the correct serial number for the RCT3000 - fixed bug #702: A problem introduced in release 3.1.0 could block all communication to MiniModule behind Service Adapter as well as i to RackExpansions. =============================================================== LYNX Device Controller - RELEASE 3.1.0 (build 157, 13.Feb.2006) COMPATIBLE with client software 3.1.0 and above (c3_local / RCP). ------------------------------------------------ Fixes - fixed bug that could lead to a situation in which the server application would not react to remote-IF commands anymore. This would also imply a general performance impact on the server application (very slow response to any event, network command etc.) =============================================================== LYNX Device Controller - RELEASE 3.0.1 (build 156, 24.Jan.2006) COMPATIBLE with client software 3.0.0 and above (c3_local / RCP). ------------------------------------------------ Fixes - fixed bug #688: DVA5110: status LED color in UI sometimes not correct In the UI (GUI/RCP5000/...) the color of the status LED of theDVA5110 was sometimes not correct (i.e. not same color as LED on the board itself) - fixed bug #696: Sending repeated Read-Subscribe ('RS') commands over the LYNX Remote Interface would ultimatively lead to RCT5030 system instability (after ~1 million such commands) =============================================================== LYNX Device Controller - RELEASE 3.0.0 (build 155, 23.Dec.2005) COMPATIBLE with client software 3.0.0 and above (c3_local / RCP). NOTE: this version is the required minimum for using the Backup/Restore functionality in the PC-GUI (c3_local) application. ------------------------------------------------ RCP5000 FEATURES - Added User Interface for DVD5420 (SDI / ASI distribution amplifier with reclocking / inversion) - Added User Interface for SVD5082 (SDI Input Switch 2*8 -> 2) ------------------------------------------------ Fixes - Added general stability by fixing several minor weaknesses in the internal processing. - fixed bug #649: "strange UI status text if SVD5012 in bypass" The status text in the user interface (GUI / RCP5000) was confusing when the unit was running in "bypass mode". - fixed bug #658: "SDI input missing" event available for just one channel The Events-Tab in the GUI of the CAD3002 showed only events for one of the two channels. - fixed bug #662: "PMX3312/3313 does not show events of AudioADC" Input-lost Events from Audio-ADC combo are not shown in GUI of PMX3312 / PMX3313 - fixed bug #665: "RCP5000: low performance with several modules" Several modules (mainly CADxxxx) take a long time to appear in the RCP5000 local display. Optimized some UI-algorithms to fix this. =============================================================== LYNX Device Controller - RELEASE 2.8.4 (build 154, 02.Dec.2005) COMPATIBLE with client software 2.8.0 and above (c3_local / RCP). ------------------------------------------------ Fixes - fixed bug #672: Device server: intermittent restarts on PAD5212. Eliminated an incompatibility between the PAD5212 (Audio Delay Line) and the Device server (RCT5030 / RCP5000) that would lead to an intermittend restart of the server process. This did lead to a cyclic re-login of connected clients. - fixed bug #673: fixed problem in RCP5000 XML-configuration framework that would lead to restarts of the RCP5000 panel server on certain constructs. =============================================================== LYNX Device Controller - RELEASE 2.8.3 (build 153, 29.Nov.2005) COMPATIBLE with client software 2.8.0 and above (c3_local / RCP). ------------------------------------------------ RCP5000 FEATURES - added control of Audio Routing parameters for PVD5005 / PVD5010. To simplify the configuration of the complex crossbars through the RCP user interface, these controls let the user connect input and output points of the internal crossbar as single operations. (I.e. the actual crossbar connection points are not directly accessible from the RCP) - added boolean configuration parameter RCP_NAVIGATION_STAY_IN_DEVICE (default value: FALSE). It can be modified through the RCP5000's Web-Interface. By setting it to TRUE, the RCP pushbuttons can be used to navigate within multiple devices of the same type rather than between devices. E.g., in a system with several PVD5010, different parameter groups can be assigned to different buttons (by manually navigating to the parameters and then assigning the buttons). When later navigating to a different device of the same type, pushing a button doesn't navigate back to the device the button has been assigned to, but just jumps to the assigned parameter within the current device. ------------------------------------------------ RCT5030 FEATURES - added boolean configuration parameter SNMP_TRAP_FORCE_LEVEL_CLEARED (default: TRUE). It can be modified through the RCT5030's Web-Interface. Setting this value to TRUE (the default) will force the 'eventLevel' (OID 14755.4.3.2) to value '6' ('cleared') if the event is cleared, i.e. if 'eventOn' (OID 14755.4.3.4) is '0'. Otherwise (FALSE), the 'eventLevel' will reflect the level of the original event (e.g. 'error'), even if the trap is announcing the event as cleared (not active anymore).", ------------------------------------------------ Fixes - fixed bug #600: Modifying the IP settings of the RCT5030/RCP5000 requires a restart of the embedded software applications, so that the CORBA-ORB can adapt to the new network parameters. This is done automatically now. - fixed bug #566: Setting string-type variables to empty string "" on the WEB-Interface (page "Server Configuration") did not work correctly. - fixed bug #567: Setting configuration variable RCP_DISPLAY_SEPARATOR_CHAR to the empty string "" would display strange (undefined) characters in the separation column in the RCP display. =============================================================== LYNX Device Controller - RELEASE 2.8.2 (build 152, 07.Nov.2005) COMPATIBLE with client software 2.8.0 and above (c3_local / RCP). ------------------------------------------------ Fixes - fixed bug #645 (RCT5030): SNMPTraps sent under wrong OID The SNMP-MIB (LYNX-TRAPS-MIB.txt) declares the OID for Device-Traps as 1.3.6.1.4.1.14755.3.1. However, traps were sent with the OID 1.3.6.1.4.14755.3.2.0. This inconsitency has been fixed. (The MIB remains unchanged, the Traps are now sent correctly) =============================================================== LYNX Device Controller - RELEASE 2.8.1 (build 151, 25.Oct.2005) COMPATIBLE with client software 2.8.0 and above (c3_local / RCP). ------------------------------------------------ Fixes - fixed bug #651: Single parameter in UI not updated. In few UIs (depending on board type) one single parameter might not be updated correctly. =============================================================== LYNX Device Controller - RELEASE 2.8.0 (build 150, 24.Oct.2005) COMPATIBLE with client software 2.8.0 and above (c3_local / RCP). ------------------------------------------------ RCP5000 FEATURES - Added User Interface for PTG5010 (SDI Test Signal Generator) - Added User Interface for PVD5000 (same as PVD5000G FRamesynchronnizer, without GPI input) - Added User Interface for CMX5110 (Deembedder with Analog Video and Analog Audio Output) - Added User Interface for PMX5212/PMX5214 (BS509500) (new AES Embedders, based on PCB BS509500) - Added User Interface for DVD5620 (Multi-Format HD/SD SDI Distribution Amplifier) - Added User Interface for SVD5012 (SDI Change-Over Switch) ------------------------------------------------ Fixes - increased server stability by major software framework improvements. =============================================================== LYNX Device Controller - RELEASE 2.7.1 (build 149, 16.Sept.2005) COMPATIBLE with client software 2.7.0 and above (c3_local / RCP). ------------------------------------------------ Fixes - fixed bug #602: sync source of CAD5121/CAD5122 is identical for both channels. The sync source of CAD5121/CAD5122 (intern/extern/off) is always identical for channels 1 and 2. The client display (PC-GUI / RCP5000) was not guaranteed to be updated accordingly. - fixed bug #638: Presence of SW-Licenses not recognized correctly The presence of a software license was not always correctly recognized in the RCT5030. This affected the SNMPTraps and LYNXRemoteControl options. =============================================================== LYNX Device Controller - RELEASE 2.6.8 (build 146, 02.Aug.2005) COMPATIBLE with client software 2.6.0 and above (c3_local / RCP). ------------------------------------------------ RCP5000 Fixes - A device that had never been locked before could be displayed as "locked", while the lock was in fact not active. Workaround was to lock/unlock the device once. - fix a couple of display issues with user-defined panel-configurations =============================================================== LYNX Device Controller - RELEASE 2.6.7 (build 145, 01.Aug.2005) COMPATIBLE with client software 2.6.0 and above (c3_local / RCP). ------------------------------------------------ RCP5000 FEATURES - The current host's IP address is shown in the HOME-display (top right corner) - Current Server Connection is saved persistently. At application startup, the last current server connection is selected again. ------------------------------------------------ RCP5000 Fixes - fixed bug #613: navigating a large (flat) list of devices could show incorrect total number of devices. Navigation of such a list could break in th middle (jump back to head). - fixed bug #618: Switching the LOCATE function of a device on/off very quickly (by turning the associated digi-pot very quickly), could leave the panel non-responsive for a while. - fixed bug #619: locking a device in one RCP5000 (device-parameter LOCK) was not properly propagated into other (passive) RCP5000s that are connected to the same device. - fixed bug: executing commands from XML user-configuration did not work correctly under certain conditions. =============================================================== LYNX Device Controller - RELEASE 2.6.6 (build 144, 21.July.2005) COMPATIBLE with client software 2.6.0 and above (c3_local / RCP). ------------------------------------------------ RCP5000 Fixes - allow to control multiple devices from one RCP5000 menu page. - make sure the RCP5000 connects to a rack without complaining about "no option RCP" ------------------------------------------------ NOTE: On RCT5030 platforms with build label XBOARD_130 or older, this package can only be installed over RELEASE 2.6.4. -> If you are using a platform build XBOARD_130 or older, you will have to install RELEASE 2.6.4 before installing this package. -> You can find the platform build label on the "System settings" page on the Web-Interface of your RCT5030. (see RCT5030 manual, section "Controller Configuration") =============================================================== LYNX Device Controller - RELEASE 2.6.4 (build 142, 14.July.2005) COMPATIBLE with client software 2.6.0 and above (c3_local / RCP). ------------------------------------------------ Fixes - removed unnecessary restart of device server after a current client is not reachable anymore. The appropriate auto-cleanup (which had been introduced in RELEASE 2.6.2, see below) was deciding on a very fundamental cleanup strategy in certain situations that turned out not to be necessary. ------------------------------------------------ NOTE: Installing this package on a RCT5030 platform with build label XBOARD_130 or older will ugrade the platform with extension #1. This is a required extension for all future software packages for such older platforms. -> If you are using a platform build XBOARD_130 or older, you will have to install this package before installing any newer package. -> You can find the platform build label on the "System settings" page on the Web-Interface of your RCT5030. (see RCT5030 manual, section "Controller Configuration") =============================================================== LYNX Device Controller - RELEASE 2.6.3 (build 140, 24.June.2005) COMPATIBLE with client software 2.6.0 and above (c3_local / RCP). ------------------------------------------------ Fixes - fixed bug #604: incorrect read of data from the PAD5212 could lead to wrong display values on the client (c3_local / rcp). =============================================================== LYNX Device Controller - RELEASE 2.6.2 (build 138, 21.June.2005) COMPATIBLE with client software 2.6.0 and above (c3_local / RCP). ------------------------------------------------ Fixes - Fixed general connection issue: after a client had disconnected, some references to that client would still be held in parts of the running server. Next time when certain values (that these clients had been interested in) are changed, these references had to be removed before the new info could be propagated to the current clients. This did result in noticable delays in certain situations (such as initial login of a client, speed of update in case of multiple clients). =============================================================== LYNX Device Controller - RELEASE 2.6.1 (build 137, 09.June.2005) COMPATIBLE with client software 2.6.0 and above (c3_local / RCP). - Supply some additional (optional) status information to the various SW-clients of the 2.6.0 release (RCP5000, RCPSimulation and c3_local). - Enabling a SoftwareOption in the RCT5030 from a client (e.g. c3_local) will automatically be propagated to other clients. In previous versions of the RCT5030 software, such other clients had to disconnect/reconnect in order to become aware of the mofified status of the SoftwareOption. - General rework of major parts of the software architecture, resulting in a significant increase in overall stability and performance. ------------------------------------------------ Fixes - fix bug #590: "GUI CAD5320: left/right indication crossed" The indication of input channel status was crossed between left and right channel on the GUI of the CAD5320. This server version is required for the Event- and general Status information to appear correct in the client UI. =============================================================== LYNX Device Controller - RELEASE 2.5.3 (build 132, 17.May.2005) COMPATIBLE with c3_local 2.5.0 and above. ------------------------------------------------ Fixes - fix bug: Prevent from intermittend situations where (after a logout) the re-login into the server from same client was refused. =============================================================== LYNX Device Controller - RELEASE 2.5.2 (build 131, 25.Apr.2005) COMPATIBLE with c3_local 2.5.0 and above. ------------------------------------------------ Fixes - fix bug #577: "update to GUI not always complete" A changed register value in a device (by local adjustment on board or by GUI/RCP5000) was sometimes not propagated to all connected clients (RCP5000, other GUIs). This problem is not existent in releases prior to 2.5.1 =============================================================== LYNX Device Controller - RELEASE 2.5.1 (build 130, 14.Apr.2005) COMPATIBLE with c3_local 2.5.0 and above. ------------------------------------------------ Fixes - fix bug: the status text of the CDX5024 was sometimes not 100% accurate in the GUI. This status text is generated in the server, hence this fix. =============================================================== LYNX Device Controller - RELEASE 2.2.9 (build 127, 21.Mar.2005) COMPATIBLE with c3_local 2.2.3 and above. ------------------------------------------------ Fixes - fix bug #555: "c3-framework shutdown on CAD3110" Some versions of the CAD3110 shutdown the RCT5030. Fixed by eliminating a long-hidden bug in the framework. (NOTE: this bug affects an RCT5030, when connected to a CAD3110 with version < 124 in a Series3000 Rack) =============================================================== LYNX Device Controller - RELEASE 2.2.8 (build 124, 02.Mar.2005) COMPATIBLE with c3_local 2.2.3 and above. ------------------------------------------------ Fixes - fix bug #551: "RCT5030 takes a long time to login if a previous client died" When a client (c3_local) logs into the RCT5030 and then does not properly logout, the next attempt to login to the RCT5030 will take a long time (~ 30 sec.) - fix bug #552: "RCT5030 WebIF: large logfile.txt leads to timeout on logfile page" If one of the logfiles is very large (this has been observed with a ~8 MB file), then the complete Logfile-page is not given out by the Webserver anymore. Instead, this message sent to the HTTP-client: Fatal error: Maximum execution time of 30 seconds exceeded in /usr/local/lynx/c3_server/2.2.6/web/code/ClassC3Logfiles.php on line 28 - fix bug #554: "RCT5030 instable under heavy load." under very heavy load, the RCT5030 seems to restart itself from time to time. A c3_local GUI is logged out spontaneously, and a re-login takes long time to complete. =============================================================== LYNX Device Controller - RELEASE 2.2.7 (build 122, 24.Feb.2005) COMPATIBLE with c3_local 2.2.3 and above. ------------------------------------------------ Fixes - fix bug #541: "initial (color/text) status of some devices wrong" The initial status of about 1% of devices in the GUI is not correct (text/color is OK/green instead of the appropriate value). Pressing F5 in the devices GUI brings the status up to correct content. This is a statistical error, not 100% reproducible per device. - fix bug #545: "c3_server does not allow to login anymore" The c3_server application (inside RCT5030) can get into a state where no more logins from a client (c3_local) are possible. The only way out of this situation is to restart the c3_server, either by power-cycling the RCT5030 or by restarting the app through the web-interface. =============================================================== LYNX Device Controller - RELEASE 2.2.6 (build 121, 14.Feb.2005) COMPATIBLE with c3_local 2.2.3 and above. ------------------------------------------------ Fixes - fix bug #541: " initial (color/text) status of some devices wrong" The initial status of about 1% of devices in the GUI is not correct (text/color is OK/green instead of the appropriate value). Pressing F5 in the devices GUI brings the status up to correct content. This is a statistical error, not 100% reproducible per device. =============================================================== LYNX Device Controller - RELEASE 2.2.5 (build 120, 10.Feb.2005) COMPATIBLE with c3_local 2.2.3 and above. ------------------------------------------------ New Features This is a feature release, adding support for the generic status reporting model. This will make it possible, that for future releases of individual device types, the c3_server does not necessarily have to be updated anymore. It is declared as bugfix-release 2.2.5 anyways (should have been 2.3.0), so that the same c3_local GUI version can be connected as before. (no need to upgrade c3_local for this release) A new Web-Interface allows for configuration of all relevant parameters of the network-interface (gateway, netmask, broadcast addr.) =============================================================== LYNX Device Controller - RELEASE 2.2.4 (build 119, 10.Feb.2005) COMPATIBLE with c3_local 2.2.3 and above. ------------------------------------------------ Fixes - fix bug #538: "RCT5030 version 2.2.3 does not run with RCT5010" c3_server version 2.2.3 cannot be used with RCT5010. =============================================================== - end of file